MJS002A |
Deep UV uvc-led module |
The bottom of the module is equipped with flange edge and two mounting holes, which is suitable for static UVC led bacteriostatic module for bacteriostasis of air and liquid; The recommended opening size is 16.7 ± 0.3 mm.
This product is widely used in water dispenser, ice maker, air humidifier, air purifier, aromatherapy machine, pet water dispenser, dishwasher and other products.
Optical power
wavelength
Atmosphere lamp
Voltage
current
GB/T 4827-2015
Water related safety: meet the requirements of water batch and food hygiene and safety
Specification of terminal wire: 2pin, xhb2 54-2p, red and black wire, wire diameter 1.6mm, white terminal;
Terminals can be customized according to customer requirements.
Constant voltage drive: DC12V
Lead specification: ul1007, 22Awg parallel wire, wire length 150mm
Terminal specification: 2pin
Waterproof grade: module front (quartz window surface) IP68 dust-proof and waterproof (excluding terminal)
Service temperature: - 25 ~ 40 ℃
Insulation withstand voltage: DC500v + 2vin / 1 min
Item | Symbol | Min. | Typ. | Max. | Unit |
---|---|---|---|---|---|
working voltage | Vf | / | 12 | / | V |
Driving current | If | / | 40 | / | mA |
Peak wavelength | λp | 270 | / | 280 | nm |
Optical power | P0 | 4 | / | 6 | mW |
Irritation angle | 2θ1/2 | / | 120 | / | deg. |
UV power test: using the integrating sphere, the UV power output of the test module is the specified value;
UV wavelength range test: 270 ~ 280 nm;
Insulation withstand voltage test: apply ac1500 V, 50Hz voltage between the live part and the shell for 1min without breakdown& nbsp;
High and low temperature test: the product can work reliably within the temperature range of - 25 ~ 40 ℃; It can be stored reliably within the temperature range of - 40 ℃ ~ 85 ℃.